Sign in →

Test Code ALUMM Aluminum, Serum

Additional Codes

Mayo AL
Epic ID LAB665

 

Specimen Type

Serum


Specimen Required


Patient Preparation: High concentrations of gadolinium and iodine are known to potentially interfere with most inductively coupled plasma mass spectrometry-based metal tests. If either gadolinium- or iodine-containing contrast media has been administered, a specimen should not be collected for 96 hours.

Supplies:

-Metal Free B-D Tube (No Additive), 6 mL (T184)

-Metal Free Specimen Vial (T173)

Container/Tube: 6-mL Plain, royal blue-top Vacutainer plastic trace element blood collection tube

Submission Container/Tube: 7-mL Mayo metal-free, screw-capped, polypropylene vial

Specimen Volume: 1.2 mL Serum


UPH Waterloo Region Lab Test Catalog Note:

Collect 1.2mL serum in plain royal blue trace element tube. Serum must be separated from cells within 2 hours of collection and poured off into a metal free, screw cap pour off tube.

Specimen Minimum Volume

Serum: 0.3 mL

Specimen Stability Information

Specimen Type Temperature Time Special Container
Serum Refrigerated (preferred) 28 days METAL FREE
  Ambient  28 days METAL FREE
  Frozen  28 days METAL FREE
UPH Waterloo Region Lab Test Catalog Note:

Transport refrigerated in metal free pour off tube. 

Reject Due To

Gross hemolysis OK
Gross lipemia OK
Gross icterus OK

Performing Laboratory

Mayo Clinic Laboratories in Rochester

Method Name

Triple-Quadrupole Inductively Coupled Plasma Mass Spectrometry (ICP-MS/MS)

Useful For

Monitoring for aluminum toxicity in patients undergoing dialysis

 

Routine aluminum screening

 

Monitoring metallic prosthetic implant wear

Day(s) Performed

Monday through Friday

Report Available

1 to 4 days

Reference Values

<7 ng/mL

<60 ng/mL (dialysis patients)

 

For International System of Units (SI) conversion for Reference Values, see www.mayocliniclabs.com/order-tests/si-unit-conversion.html

CPT Code Information

82108