Test Code DIAZPM Diazepam and Metabolites, Serum
Additional Codes
| Mayo | DIA |
| Epic ID | LAB468 |
Specimen Type
Serum RedSpecimen Required
Supplies: Sarstedt Aliquot Tube, 5 mL (T914)
Collection Container/Tube: Red top (Serum gel/SST are not acceptable)
Submission Container/Tube: Plastic vial
Specimen Volume: 1 mL
Collection Instructions: Centrifuge and aliquot serum into a plastic vial.
Specimen Minimum Volume
0.3 mL
Specimen Stability Information
| Specimen Type | Temperature | Time |
|---|---|---|
| Serum Red | Refrigerated (preferred) | 28 days |
| Ambient | 28 days | |
| Frozen | 28 days |
Transport refrigerated.
Reject Due To
| Gross hemolysis | OK |
| Gross lipemia | OK |
| Gross icterus | OK |
Performing Laboratory
Mayo Clinic Laboratories in Rochester
Method Name
Liquid Chromatography Tandem Mass Spectrometry (LC-MS/MS)
Useful For
Assessing compliance
Monitoring for appropriate therapeutic level
Assessing diazepam toxicity
Day(s) Performed
Wednesday
Report Available
3 to 7 daysReference Values
Therapeutic concentrations
Diazepam: Not established
Diazepam and Nordiazepam: 100-2,500 ng/mL
Cutoff concentrations by liquid chromatography tandem mass spectrometry:
Diazepam: 10 ng/mL
Nordiazepam: 10 ng/mL
Oxazepam: 10 ng/mL
Temazepam: 10 ng/mL
CPT Code Information
80299