Sign in →

Test Code DIGITA Digitoxin Quantitative, Serum or Plasma

Additional Codes

PathLab DIGITA
Epic ID LAB1394

 

Specimen Requirements

Container/Tube Type: 

Red (No Additive)
Lavender (EDTA)

 

Collection Information: 

Collect blood in a red serum tube or lavender (K2EDTA or K3EDTA).

 

Transport Information: 

Centrifuge and aliquot 1.0 mL of serum or plasma into a plastic transport vial. Send refrigerated.

 

Minimum Sample Volume: 

0.4 mL of serum or plasma

Stability/Transport

Temperature Stability Preferred Transport
Refrigerated 7 days X
Frozen 3 months  

 

Unacceptable Conditions

Separator tubes.

Performing Lab

ARUP Laboratories; Salt Lake City, UT

Methodology

Quantitative Immunoassay

Day(s) Performed

Varies

Report Available

5-8 days

CPT Code Information

80375 (Alt code: G0480)