Sign in →

Test Code ETHSXM Ethosuximide, Serum

Additional Codes

Mayo ETX
Epic ID LAB683

 

Specimen Type

Serum


Specimen Required


Supplies: Sarstedt Aliquot Tube, 5 mL (T914)

Collection Container/Tube:

Preferred: Serum gel

Acceptable: Red top

Submission Container/Tube: Plastic vial

Specimen Volume: 0.5 mL

Collection Instructions:

1. Serum gel tubes should be centrifuged within 2 hours of collection.

2. Red-top tubes should be centrifuged and the serum aliquoted into a plastic vial within 2 hours of collection.


Specimen Minimum Volume

0.25 mL

Specimen Stability Information

Specimen Type Temperature Time
Serum Refrigerated (preferred) 14 days
  Frozen  28 days
  Ambient  14 days
UPH Waterloo Region Lab Test Catalog Note:

Transport refrigerated.

Reject Due To

Gross hemolysis Reject

Performing Laboratory

Mayo Clinic Laboratories in Rochester

Method Name

Enzyme-Multiplied Immunoassay Technique (EMIT)

Useful For

Monitoring ethosuximide therapy

 

Determining compliance

 

Assessing ethosuximide toxicity

Day(s) Performed

Monday through Saturday

Report Available

Same day/1 day

Reference Values

Therapeutic: 40-100 mcg/mL

Critical value: >150 mcg/mL

CPT Code Information

80168