Sign in →

Test Code HAPT Haptoglobin

Additional Codes

PathLab HAPT
Epic ID LAB89

 

Specimen Requirements

Preferred Collection Container: 

Light Green (Lithium Heparin Plasma Separator Tube)
SST (Serum Separator)

 

Also Acceptable Collection Container: 

Green No Gel (Lithium Heparin)
Red (No Additive)

 

Collection Information: 

Collect blood in a light green plasma separator tube or serum separator tube.

 

Transport Information: 

Centrifuge and aliquot 1.0 mL of serum or plasma into a plastic transport vial. Send refrigerated.

 

Minimum Sample Volume: 

0.2 mL serum or plasma 

 

Stability Comments: 

Serum or plasma should be physically separated from contact with cells as soon as possible.

Stability/Transport

Temperature Stability Preferred Transport
Refrigerated 30 days X
Room Temp 3 months  

 

Performing Lab

Pathology Laboratory

Methodology

Immunoturbidometric

Day(s) Performed

Daily

Report Available

2 hours

CPT Code Information

83010