Test Code HBAT Hepatitis Acute Panel
Additional Codes
| Epic ID | LAB551 |
Specimen Requirements
Preferred Collection Container: green top lithium heparin tube, SST
Also Acceptable Collection Container: serum red top tube or EDTA purple top tube
Collection Information:
Collect 3.0 mL of Lithium heparinized plasma or serum.
Serum or plasma must be separated from cells within 2 hours of collection.


Stability/Transport
| Temperature | Stability | Preferred Transport |
| Refrigerated | 7 days | X |
Unacceptable Conditions
Hemolysis
Performing Lab
Allen Hospital Laboratory
Panel
Includes: Hepatitis Bs Antigen (HBsAg), Hepatitis Bc Antibody IgM (Anti-HBcIgM), Hepatitis A IgM, and Hepatitis C Antibody (Anti-HCV)
Day(s) Performed
Monday-Friday
Report Available
1-3 days
Reference Ranges
See individual tests in panel.
CPT Code Information
80074