Test Code SFCRYP Cryptococcus Antigen, CSF
Additional Codes
| PathLab | SFCRYP |
| Epic ID | LAB927 |
Specimen Requirements
Container/Tube Type:
Sterile CSF Container
Collection Information:
CSF
Transport Information:
1.0 mL CSF
Minimum Sample Volume:
0.1 mL
Remarks:
Positive specimens will reflex automatically to a titer. (SQ Code: SFCRTR; CPT: 87327).
Unless monitoring therapy for previous infection, the Cryptococcal Antigen Test should be used in conjunction with fungal culture, and is not an acceptable substitute for culture of CSF.
Stability/Transport
| Temperature | Stability | Preferred Transport |
| Refrigerated | 72 hours | X |
| Frozen | Indefinitely | |
| Room Temp | Not Acceptable |
Performing Lab
Pathology Laboratory
Methodology
Lateral Flow Enzyme Immunoassay
Day(s) Performed
Daily
Report Available
1 hour
CPT Code Information
87899